U.S. flag

An official website of the United States government

Format

Send to:

Choose Destination

SRX24935632: GSM8330380: H37Rv WT Rep3; Mycobacterium tuberculosis H37Rv; RNA-Seq
1 ILLUMINA (NextSeq 2000) run: 10.4M spots, 525.6M bases, 178.5Mb downloads

External Id: GSM8330380_r1
Submitted by: Institut Pasteur
Study: Role of whiB6 and kdpDE in the successful multidrug-resistant clone Mycobacterium tuberculosis B0/W148 [whiB6_RNA-seq]
show Abstracthide Abstract
Among the multidrug-resistant (MDR) clones of Mycobacterium tuberculosis (Mtb) that were epidemiologically particularly successful, the 100-32 MDR Beijing clone, also called B0/W148 clone, has emerged since the early sixties. These B0/W148 strains belonging to the lineage 2 within the global Mtb phylogeny, are the main contributors to the MDR epidemic in Russia and Eastern Europe, and since the USSR's fall, have also propagated to Western Europe. Among the various mutations that were identified as being specific for the MDR B0/W148 clone, we focused on two found in the transcriptional regulators KdpDE and WhiB6 and characterized in a H37Rv strain background the transcriptional profile associated with these mutations and their potential impact on the in vitro and in vivo growth characteristics. Overall design: Gene expression profiling by RNA-seq of the effect induced by the mutation T51P in whiB6 of M. tuberculosis H37Rv cultured in normal growth condition
Sample: H37Rv WT Rep3
SAMN41846233 • SRS21639963 • All experiments • All runs
Library:
Name: GSM8330380
Instrument: NextSeq 2000
Strategy: RNA-Seq
Source: TRANSCRIPTOMIC
Selection: cDNA
Layout: SINGLE
Construction protocol: Bacterial strains were pelleted and bead beated in 1 mL of TRIzol (Life Technologies) with 0.1 mm silica beads (MP Biomedicals). After centrifugation, supernatants were extracted with chloroform, and RNA was precipitated with isopropanol and glycogen. RNA pellets were washed with 75% ethanol and dissolved in RNase-free water. Contaminant DNA was removed by incubation with DNase (TURBO DNA-free kit, Life Technologies). RNA cleanup was performed with the RNeasy Mini Kit (Qiagen). RNA integrity and quality were assessed with an Agilent Bioanalyzer device (Agilent Technologies). RNA-seq libraries were prepared using the Stranded Total RNA Prep and Ligation with Ribo-Zero Plus kit (Illumina) and sequenced using a NextSeq 2000 device (Illumina).
Runs: 1 run, 10.4M spots, 525.6M bases, 178.5Mb
Run# of Spots# of BasesSizePublished
SRR2942254010,422,389525.6M178.5Mb2024-09-25

ID:
33271875

Supplemental Content

Recent activity

Your browsing activity is empty.

Activity recording is turned off.

Turn recording back on

See more...